Laboratories Equipment Transformer Dielectric Loss Analyzer Capacitance & Tan Delta Meter

Product Details
Customization: Available
Accuracy Grade: 0.5
Display: Digital
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 7 patents, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (22)
  • Laboratories Equipment Transformer Dielectric Loss Analyzer Capacitance & Tan Delta Meter
  • Laboratories Equipment Transformer Dielectric Loss Analyzer Capacitance & Tan Delta Meter
  • Laboratories Equipment Transformer Dielectric Loss Analyzer Capacitance & Tan Delta Meter
  • Laboratories Equipment Transformer Dielectric Loss Analyzer Capacitance & Tan Delta Meter
Find Similar Products

Basic Info.

Power Source
AC220V
High Voltage Output
0.5kv~10kv
Accuracy
2%
Max Current
200mA
Capacity
2000va
Self-Exited Power Supply
AC 0V~50V/15A
Resolution
Tgδ: 0.001%; Cx: 0.001PF
Measurement Range of Tgδ
Unrestricted
Measurement Range of C X
15PF < Cx <300NF
Measurement Range of CVT Test
Cx < 300 NF
CVT Ratio Range
10~10000
CVT Ratio Precision
0.1%
CVT Ratio Resolution
0.01
Transport Package
Wooden Box
Specification
ISO9001, ISO14001, OHSAS18001
Trademark
United Electrical
Origin
Wuhan, China
HS Code
9030339000

Product Description

Application:
HZGS-208 automatic dielectric loss tester is a high-precision dielectric loss tangent value and capacitance test instrument for various high-voltage power equipment in power plant, substation and other fields or laboratories. The instrument is an integrated structure with built-in dielectric loss test bridge, variable frequency voltage-regulating power supply, booster transformer and SF6 high stability standard capacitor. The test high voltage source is generated by the inverter inside the instrument and is used for the test of the test object after the transformer is boosted. Frequency can be changed into 50Hz, 47.5Hz\52.5Hz, 45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz, digital notch wave technology is adopted to avoid interference of power frequency electric field on the test, which fundamentally solves the problem of accurate measurement under the interference of strong electric field. At the same time, it is suitable for the detection of generator power supply after power failure. The instrument is equipped with insulation oil cup and temperature control device to test insulation oil dielectric loss.

Features:

1.Super LCD display
Operation is simple. The instrument is equipped with a high quality full-touch LCD screen and a super-large full-touch operation interface. Each process is very clear and clear. It is an ideal intelligent dielectric loss measuring device at present.
2.Mass storage data
The instrument is equipped with a calendar chip and a large-capacity memory, which can store 200 sets of data. The test results can be saved in chronological order, the history can be viewed at any time, and the output can be printed.
3.Scientific and advanced data management
Instrument data can be exported through U disk, and can be viewed and managed on any PC through our company's special software.
4.Multiple test modes
The instrument can be tested by internal high voltage, external high voltage, internal standard, external standard, positive wire method, negative wire method, self-excitation method and other methods.High voltage (greater than 10kV) dielectric loss can be achieved under external standard external high voltage.
5.CVT test by one step at a time
The instrument can also test the dielectric loss and capacitance of CVT (capacitive voltage transformer) C1 and C2, realizing the simultaneous test of C1 and C2.The instrument can also test the CVT ratio and voltage Angle difference.
6.Measuring CVT without removing high voltage lead
The instrument can correctly measure the dielectric loss and capacitance of CVT without removing the high voltage lead of CVT.
7.CVT negative wire shielding method measuring C0
The instrument can measure the dielectric loss and capacitance of C0 at the upper end of CVT by negative wire shielding method.
8.High speed sampling signal
The inverter and sampling circuit inside the instrument are all controlled by digitalization, and the output voltage is continuously adjustable.
9.Multiple protection is safe and reliable
The instrument has multiple protection measures such as input voltage fluctuation, high voltage current, output short circuit, power supply fault, over-voltage, over-current, temperature and so on, which ensures the safety and reliability of the instrument.The instrument also has the function of grounding detection to ensure that ungrounded devices are not allowed to boost voltage.

Main Parameters:
1 Working condition -15ºC~40ºC RH<80%
2 Anti-interference principle variable-frequency method
3 Power supply AC 220V±10% Permissible generator
4 High Voltage Output 0.5KV~10KV Every other 0.1kV
Accuracy 2%
Max current       200mA
Capacity 2000VA
5 Self-exited power supply AC 0V~50V/15A 50HZ,60HZ single frequency
45HZ/55HZ
47.5HZ/52.5HZ
55HZ/65HZ   57.5HZ/62.5HZ
Automatic dual frequency conversion
6 Resolution tgδ: 0.001% Cx: 0.001pF
7 Accuracy △tgδ:±(reading*1.0%+0.040%)
△C x :±(reading*1.0%+1.00PF)
8 Measurement range tgδ unrestricted
C x 15pF < Cx < 300nF
10kV Cx < 60  nF
 5kV Cx < 150 nF
 1kV Cx < 300 nF
CVT test Cx < 300 nF
9 CVT ratio range 10~10000
CVT ratio precision 0.1%
CVT ratio resolution 0.01
10 Size of host machine (mm) 350(L)×270(W)×270(H)
Size of accessory case (mm) 350(L)×270(W)×160(H)
11 Memory size 200 sets   support U disk data storage
12 Weight of host machine 22.75Kg
Weight of accessory case 5.25Kg

Company Profile
Wuhan Hezhong Electric Equipment Manufacture Co., Ltd is a high-tech enterprise professionally engaged in R & D, manufacture and marketing of power testing products, instruments, power industry automation systems for 20 years.We export completed set to Korea, Singapore, Vietnam, India, Ecuador, Paraguay, Pakistan, Philippines, Russia, Italy, Austria, Portugal, Chile such as PD test system, impulse voltage generator, temperature rising test system, transformer comprehensive test system, cable fault detect system and varies of instruments for transformer, circuit breaker, switchgear, lightning arrestor, insulator, cable, battery,SF6 gas and so on.
Laboratories Equipment Transformer Dielectric Loss Analyzer Capacitance &amp; Tan Delta MeterCompetitive Products
Laboratories Equipment Transformer Dielectric Loss Analyzer Capacitance &amp; Tan Delta MeterCertifications
Laboratories Equipment Transformer Dielectric Loss Analyzer Capacitance &amp; Tan Delta MeterCustomer Visit
Laboratories Equipment Transformer Dielectric Loss Analyzer Capacitance &amp; Tan Delta Meter

On-site Service
Laboratories Equipment Transformer Dielectric Loss Analyzer Capacitance &amp; Tan Delta Meter

Package and Delivery
Laboratories Equipment Transformer Dielectric Loss Analyzer Capacitance &amp; Tan Delta Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier