High Voltage Testing Transformer DC Hipot Tester

Product Details
Customization: Available
Output Voltage (Kv): 0~500kv
Output Current (Ma): 0~20mA
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 7 patents, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (22)
  • High Voltage Testing Transformer DC Hipot Tester
  • High Voltage Testing Transformer DC Hipot Tester
  • High Voltage Testing Transformer DC Hipot Tester
  • High Voltage Testing Transformer DC Hipot Tester
  • High Voltage Testing Transformer DC Hipot Tester
  • High Voltage Testing Transformer DC Hipot Tester
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Competitive Products
  • Certifications
  • Customer Visit
  • On-site Service
  • Package and Delivery
Overview

Basic Info.

Model NO.
ZGF-120
Ripper Coefficient
≤±1%
Voltage Adjust Accuracy
≤0.5%
Measurement Accuracy
≤0.5%
Over-Voltage Setting Error
≤1.0%
0.75 Switching Error
≤0.5%
Max Resolution
≤0.1%
Environment Temperature
≤85hr
Transport Package
Wooden Box with Wrapping Film
Trademark
United Electrical
Origin
Hubei, China
HS Code
9030339000

Product Description

Product Description

DC high voltage generator is mainly used in the electric power department, power department of industrial and mining, metallurgy, iron and steel enterprise for zinc oxide lightning arrester, power cables, transformers, circuit breakers, generators and other high voltage electrical equipment of DC withstand voltage test or DC leakage current test. 

1. the case is portable and convenient to carry.
2. Using AIPWM technology, adjusts the PWM inaccuracy linearity make the accuracy is greatly improved. The ripple coefficient is less than 1%.
3. AI zinc oxide arrester and oil immersed transformer measuring function can directly save experiment report, and the accuracy is less than 1%. Keep manual 0.75 UDC1mA.
4. Used the AI technology screen setting over-voltage protection and over-current protection to replace the digital dial switch only can set voltage value, cannot set current value and voltage drift problem. Error of 1% or less.
5. The full measuring range smoothly adjust pressure, voltage regulation accuracy is less than 1%, stability is less than 1%, the voltage current error is less than 0.5%±1 letter.
6. with total time T1 and segmented time T2, and any voltage, current chronograph function.
7. The instrument added the calendar and time function.

Product Parameters

                                                     Specification

Technology parameter
60/2 120/2 200/2 300/5
Output Voltage (kV) 60 120 200 300
Output Current (mA) 2 2 2 5
Output power (W) 120 240 400 1500
Charging Current (mA) 3 3 5 5
Controll Case Weight(kg) 10.1 13 13.1 13.1
Double voltage cylinder weight(kg) 2.3 3.2 8.0 10
Double voltage cylinder specification(mm) Ф90
340
Ф90
470
Ф110
910
Ф110
1200
Voltage Measurement Error ±1%
Current Measurement Error ±0.5%
Over-voltage Setting Error AI technique setting over-voltage and over-current protection.
Error ≤±1%
0.75 Switch Error  0.75UDC-1mA high precision single touch button(accurancy≤±1%)is much suitable for zinc oxide arrester test.
Ripper Coefficient ≤±1%
Working Method Intermittent use: rated load for 30 minutes
1.1 times rated voltage use: 10 minutes
Working Environment Temperature:-10ºC~+40ºC
Relatived Humidity:When the room temperature is 25 ºC is not greater than 85% (no lon)
Altitude: below 1500 meters
Capacitive Load Tested product capacity no restriction
Structure Features Electrical insulation double voltage cylinder
Air insulation, no leakage
 

Company Profile

Kiyu Power is a high-tech enterprise professionally engaged in R & D, manufacture and marketing of power testing products, instruments, power industry automation systems for 20 years.We export completed set to Korea, Singapore, Vietnam, India, Ecuador, Paraguay, Pakistan, Philippines, Russia, Italy, Austria, Portugal, Chile such as PD test system, impulse voltage generator, temperature rising test system, transformer comprehensive test system, cable fault detect system and varies of instruments for transformer, circuit breaker, switchgear, lightning arrestor, insulator, cable, battery,SF6 gas and so on.
High Voltage Testing Transformer DC Hipot Tester

Competitive Products

High Voltage Testing Transformer DC Hipot Tester

Certifications

High Voltage Testing Transformer DC Hipot Tester

Customer Visit

High Voltage Testing Transformer DC Hipot Tester

On-site Service

High Voltage Testing Transformer DC Hipot Tester

Package and Delivery

High Voltage Testing Transformer DC Hipot Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier