No Partial Discharge Power Frequency Test Transformer and Complete Set Hipot

Type: Partial Discharge Test
Accuracy Grade: 0.5
Load Way: Electronic Load
Loading Method: Static Load
Display: Digital
Control: Computer Control
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Hubei, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 7 patents, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (22)

Basic Info.

Model NO.
CYDL
Weight
0-100Kg
Power Source
AC 220V/AC 380V
Rated Capacity
5-1000kVA
Impedance Voltage
10%
Output Voltage Waveform
Power Frequency, Sine Wave
Output Voltage
AC 0-1000kv
Surface Temperature
Oil Immersed:<55ºC Gas: <50ºC
Partial Discharge
Under Rated Voltage≤5PC
No-Load Loss
0.2%-0.35%
Insulation Method
Oil, Gas
Transport Package
Wooden Box with Wrapping Film
Specification
can be customized
Trademark
United Electrical
Origin
Hu Bei, China
HS Code
9030809090

Product Description

Application:

It is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.

Details & Features:
No Partial Discharge Power Frequency Test Transformer and Complete Set Hipot

Specification:

System Specifications

  • Power supply: 380V±10%,50/60Hz
  • Rated Capacity: 15kVA                                         
  • Output Voltage: 150kV, current: 100mA                                 
  • Short-circuit impedance: <18%
  • Operation time: 30mins@100% rated voltage and current.
    Continuous working@ 2/3 rated voltage and current.
  • Wave form distortion rate:<3% when voltage regulator input voltage distortion rate <3%.
  • PD value:≤5pC @ 100% rated voltage

1. Control unit

  • Power: AC380V±10%, 50/60Hz
  • Capacity: 15kVA
  • Output voltage: AC 0-430V
  • Rated input current: 37.5A
  • HV voltmeter range: 0-150kV
  • Timing range: 0-999s
  • Voltage and current accuracy: ≤1.5%(F.S)±2digits
  • Environment temperature: -20ºC to 50ºC

2. PD-free Gas testing transformer (HV unit)

  • Rated capacity: 15kVA
  • Input voltage: 0-400V
  • Input current: AC 0-37.5A
  • Output voltage: AC 0-150kV
  • Output current: AC 100mA
  • Voltage accuracy: AC ±0.5%
  • PC value on rated voltage: ≤5pc
  • Voltage distortion factor: <3%
  • Insulation dielectric: SF6 gas

3.Coupling capacitor

  • Rated frequency: 50/60Hz
  • Standard capacitance: 800pF±10%
  • Rated voltage: 150kV
  • Voltage ratio: 1000/1
  • Dielectric loss: <0.5%
  • Measurement accuracy: 1%
  • Permitted operation time: same with testing transformer
  • PD value: ≤5pc on 100% of rated voltage, ≤3pc on 80% of rated voltage.

4.Protective resistor

  • Rated frequency: 50/60Hz
  • Rated voltage: 150kV
  • Resistance: 8kΩ
  • Rated current: 0.1A
  • Permitted operation time: same with testing transformer

5. Isolation filter LBQ-15kVA

  • With L-C filter loop circuit, and built-in filter compensation device
  • Rated capacity: 15kVA
  • Rated voltage: 400V
  • Rated current: 37.5A
  • Frequency: 50/60Hz
  • Attenuation: 40kHz-100kHz ≥40dB
    100kHz-1.5Mhz ≥60dB
  • Permitted operation time: same with testing transformer
Company Profile:
Wuhan Hezhong Electric Equipment Manufacture Co., Ltd is a high-tech enterprise professionally engaged in R & D, manufacture and marketing of power testing products, instruments, power industry automation systems for 20 years.We export completed set to Korea, Singapore, Vietnam, India, Ecuador, Paraguay, Pakistan, Philippines, Russia, Italy, Austria, Portugal, Chile such as PD test system, impulse voltage generator, temperature rising test system, transformer comprehensive test system, cable fault detect system and varies of instruments for transformer, circuit breaker, switchgear, lightning arrestor, insulator, cable, battery,SF6 gas and so on.

No Partial Discharge Power Frequency Test Transformer and Complete Set Hipot
Competitive Products
No Partial Discharge Power Frequency Test Transformer and Complete Set Hipot

Certifications
No Partial Discharge Power Frequency Test Transformer and Complete Set Hipot

Customer Visit
No Partial Discharge Power Frequency Test Transformer and Complete Set Hipot

On-site Service
No Partial Discharge Power Frequency Test Transformer and Complete Set Hipot

Package and delivery
No Partial Discharge Power Frequency Test Transformer and Complete Set Hipot

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now