• Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity Tester
  • Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity Tester
  • Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity Tester
  • Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity Tester
  • Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity Tester
  • Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity Tester

Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity Tester

After-sales Service: Life Time
Warranty: 1 Year
Type: Insulating Oil Dielectric Loss Testing
Accuracy Grade: 2%
Display: Digital
Weight: 18kg
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Hubei, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 7 patents, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (22)

Basic Info.

Model NO.
CYJC-204A
Power Source
AC220V
High Voltage Output
1000~2200V, Per 200V
Capacity
50va, Output Current 25mA
Temperature Controlling Induction Furnac
The Max Power 500W
Temperature Controlling Range
<100ºC
Temperature Controlling Time
Room Temperature 90ºC; Less Than 20min
Transport Package
Rugged Case
Trademark
United
Origin
Wuhan, China
HS Code
9026809000

Product Description

CYJC-204A insulating oil dielectric loss tester is applied to test the dielectric loss tan delta and volume resistivity of insulating oil or other insulating liquid. The instrument adopts full digital technology, intelligently auto testing, easy to operate, the operating workers can use without much training.

Main Features
1. Integrated structure.
2. Internally integrated with dielectric oil cup, temperature controller, temperature sensor, dielectric loss testing bridge, AC testing power, standard 
capacitor, tramegger, DC high voltage power, and other main components.
3. The heating part adopts the most advanced high frequency inducting heat method, which makes the oil cup keep away from heating objects. The
heating is steady, rapid and convenient to control.
4. The AC testing power adopts AC-DC-AC switching way, effectively avoid instable voltage or frequency affecting the precision of testing.
5. The internal standard capacitor is SF6 inflating three-level type. The capacitor's dielectric loss and capacitance won't be affected by environment 
temperature and humidity, which guarantees the consistent precision after long using.
6. The instrument adopts full-digital technoloty, intelligently auto testing. 
7. LCD display, 240x180.
8. Testing result can be printed.

State indicating
1. High voltage indicator: If the high-voltage indicator is light on, means the oil cup has been with high voltage.
2. Heating indicator: If the heating indicator is light on, means the heating furnace is heating, it doesn't mean the oil cup's temperature, when the indicator is light off, please pay attention to the oil cup's high temperature.

Oil Cup' Technique
The oil cup adopts three-level structure, each level's gap is 2mm, which avoids stray capacitance and leakage affecting testing results.
(1) Distance between high voltage and low voltage: 2mm
(2) Capacitance of empty cup: 60±2pF
(3) The max testing voltage: power frequency 2000V
(4) Dielectric loss of empty cup: tgδ<1×10-4
(5) Liquid capacity: about 40ml
(6) Electrode material: stainless steel
(7) Volume: 700mm(D)*120mm(H)

Dielectric Loss Testing
The tetsting voltage is sychronizely imposed to standard capacitor and oil cup's adding-voltage pole, The testing circuit comes to PGA controlling for  two circuit signals, then sychronizely take AD samples of the two channels' signals. Then transmit digital signals to DSP(digital signal precessor), DSP carries on filtration, FFT calculation to figure out tgδ,Cx,ε and other parameters, finally transmit to CPU. 

Main Parameters
1 Using terms -5ºC~40ºC; RH<80%
2 Power AC 220V±10%, no limitation to frequency
3 High voltage output 1000V~2200V, per 200V
4 Accuracy 2%
5 Capacity 50VA, output current 25mA
6 Temperature controlling induction furnace the max power 500W
7 Temperature controlling range <100ºC
8 Temperature testing error ±0.5ºC
9 Temperature controlling error ±1ºC
10 Temperature controlling time room temperature 90ºC; less than 20min
11 Measurement range tgδ(no limitation); Cx(15pF-300pF); Rx(10M-10T)
12 Accuracy tgδ: ±(reading*1.0%+0.02%)
Cx: ±(reading*1.0+0.5pF)
Rx: ±(reading*10%)
13 Relative Dielectric Constant εr: auto calculate
14 Volume Resistivity ρ: auto calculate
15 Sizes 450(L)*310(W)*360(H)
16 Weight 18kg

Company Information:
Kiyu Power is a high-tech enterprise professionally engaged in R & D, manufacture and marketing of power testing products, instruments, power industry automation systems for 20 years.We export completed set to Korea, Singapore, Vietnam, India, Ecuador, Paraguay, Pakistan, Philippines, Russia, Italy, Austria, Portugal, Chile such as PD test system, impulse voltage generator, temperature rising test system, transformer comprehensive test system, cable fault detect system and varies of instruments for transformer, circuit breaker, switchgear, lightning arrestor, insulator, cable, battery, SF6 gas and so on.

Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity Tester
Competitive Products:
Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity TesterQualification Certificates:
Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity Tester

Customer Visit:
Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity Tester

On-site Service:
Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity Tester

Package and delivery:
Transformer Oil Dielectric Loss Tan Delta Testing Equipment Insulating Oil Volume Resistivity Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.