Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves

Product Details
Customization: Available
After-sales Service: Life Time
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 7 patents, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (22)
  • Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves
  • Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves
  • Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves
  • Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves
  • Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves
  • Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves
Find Similar Products

Basic Info.

Model NO.
CYCJ-DY(100kV-5kJ)
Type
Impulse Voltage Generator
Accuracy Grade
1
Control
Computer Control
Weight
According to The Customization
Power Source
220V, 380V
Output Peak Value
100~10000kv
T1 Wave Front Time
1.2µs±30%
T2 Wave Tail Time
50µs±20%
Reversed Overshoot
<20%
Voltage Polarity
Positive/Negative(Manual Shifting)
Waveform Shift
Auto Shifting
Charging Time
10s~999s, Set Arbitrarily
Instability of Charging Voltage
<1%
Display Screen
17 Inch TFT Colour Screen
Residual Voltage
<5kv
Voltage Testing Device
Damping Voltage Divider
Transport Package
Wooden Box with Wrapping Film
Specification
ISO9001, ISO14001, OHSAS18001
Trademark
United
Origin
Wuhan, China
HS Code
9030339000

Product Description

Impulse voltage testing system is used to analog pulse high-voltage testing equipment. 
       CYCJ-DY series impulse voltage generator is used for impulse voltage test of lightning impulse voltage full wave, lightning impulse voltage chopped wave and operation impulse voltage wave which apply to electrical equipment ect.
       Multiple waveform impulse voltage generator can produce eight kinds of waveforms of standard lightning wave, operati
on wave, lightning chopped wave, oscillating lightning wave, oscillating operation wave, line insulator steep wave, composite insulator steep wave, transformer induction operation wave.
       The technology index is in accordance with national standard and IEC standard, is in the leading position at home and has reached the
advanced level in the world.


Product Features
Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves

Product Parameters
Standard Voltage Impulse Capacitance(µF) Classes Capacitance(µF) Impulse Energy(kJ) Classes Voltage(kV) Class Weight(kg)
±300~±900 0.133~0.111 0.4~1 6~45 ±100 3~9 547~1378
±1000~±1600 0.05~0.0937 0.5~1.5 25~120 10~16 1366~1880
±1800~±2400 0.056~0.0833 0.5~1 90~240 ±200 9~12 7353~11574
±2800~±3200 0.0357~0.0625 0.5~1.5 140~320 14~16 10266~15680
±3600~±4800 0.0278~0.03125 0.5~2 80~240 18~24 15480~23500
Technique Parameters
Items 1,1.2/50µs  2,250/2500µs  3,2~5µs etc waveforms
Output Peak Value 100~10000kV
T1 Wave Front Time 1.2µs±30%
T2 Wave Tail Time 50µs±20%
Reversed Overshoot <20%
Voltage Polarity Positive/negative(manual shifting)
Waveform Shift Auto shifting
Charging Time 10s~999s, set arbitrarily
Instability of charging voltage <1%
External Input 50Hz/60Hz
Trigger Method Auto or manual, can single trigger
Trigger Maloperation rate <1%
Trigger Range 100% rated charging voltage
Display Screen 17 inch TFT colour screen
Measurement Display Precision Better than 3%
Tested Product Residual Voltage <5kV
Voltage Measurement Use damped impulse divider
Oscilloscope TBS series, optional
Insulation Strength ≤500V RMS(common to ground refer PE)
General Parameters
Power Source AC220V±10%, 50/60Hz
Environment Temperature -10±40ºC
Relative Humidity 35%-85%RH(no condensation)
Ground Resistance ≤0.5Ω
Structure Type Open structure,independent control cabinet and main body, optical fiber connection
Control Console 1.8M(length)*1.2M(height)*1M(width)
No conductive dust, no fire and explosion hazards, no corrosive metal and insulation gas, waveform
of power voltage is sine wave, distortion <5%.
Common Models to Choose
Nominal Total Voltage kV Class Impulse Capacitance (μF) Impulse Level Capacitance(μF) Total Charging Power(kJ) Application
±300~±900 3~9 0.133~0.111 0.4~1 6~45 35~110kV
±1000~±1600 10~16 0.05~0.0937 0.5~1.5 25~120 <220kV
±1800~±2400 9~12 0.056~0.0833 0.5~1 90~240 220kV~500kV
±2800~±3200 14~16 0.0357~0.0625 0.5~1.5 140~320
±3600~±4800 18~24 0.0278~0.03125 0.5~2 80~240
Minimum time D-value
between pulses
30s 40s
Generator capacity of per stage ≤1600kV, choose 100kV single-side charging  ≥1600kV, choose 100kV double-side charging

Company Profile
Kiyu Power is a high-tech enterprise professionally engaged in R & D, manufacture and marketing of power testing products, instruments, power industry automation systems for 20 years.We export completed set to Korea, Singapore, Vietnam, India, Ecuador, Paraguay, Pakistan, Philippines, Russia, Italy, Austria, Portugal, Chile such as PD test system, impulse voltage generator, temperature rising test system, transformer comprehensive test system, cable fault detect system and varies of instruments for transformer, circuit breaker, switchgear, lightning arrestor, insulator, cable, battery, SF6 gas and so on.
Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves
Competitive Products
Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves
Certifications
Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves
Customer Visit
Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves
On-site Service
Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves
Package and Delivery
Auto/Manual Control Lightning Impulse Voltage Generator for Testing Full Wave/Chopped Wave/Other Special Waves

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier