Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment

Kiyu Power Wuhan Co., Ltd
  • Audited Supplier
  • 9 yrs

Contact Supplier

Product Images of Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment

Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment pictures & photos
Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment pictures & photos
Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment pictures & photos
Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment pictures & photos
Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment pictures & photos
Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment pictures & photos
Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
  • Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
    Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
  • Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
    Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
  • Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
    Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
  • Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
    Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
  • Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
    Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
  • Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment
    Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment

Find Similar Products

Product Description

CYJC-204A insulating oil dielectric loss tester is applied to test the dielectric loss tan delta and volume resistivity of insulating oil or other insulating liquid. The instrument adopts full digital technology, intelligently auto testing, easy to operate, the operating workers can use without much training.

Main Features
1. Integrated structure.
2. Internally integrated with dielectric oil cup, temperature controller, temperature sensor, dielectric loss testing bridge, AC testing power, standard 
capacitor, tramegger, DC high voltage power, and other main components.
3. The heating part adopts the most advanced high frequency inducting heat method, which makes the oil cup keep away from heating objects. The
heating is steady, rapid and convenient to control.
4. The AC testing power adopts AC-DC-AC switching way, effectively avoid instable voltage or frequency affecting the precision of testing.
5. The internal standard capacitor is SF6 inflating three-level type. The capacitor's dielectric loss and capacitance won't be affected by environment 
temperature and humidity, which guarantees the consistent precision after long using.
6. The instrument adopts full-digital technoloty, intelligently auto testing. 
7. LCD display, 240x180.
8. Testing result can be printed.

State indicating
1. High voltage indicator: If the high-voltage indicator is light on, means the oil cup has been with high voltage.
2. Heating indicator: If the heating indicator is light on, means the heating furnace is heating, it doesn't mean the oil cup's temperature, when the indicator is light off, please pay attention to the oil cup's high temperature.

Oil Cup' Technique
The oil cup adopts three-level structure, each level's gap is 2mm, which avoids stray capacitance and leakage affecting testing results.
(1) Distance between high voltage and low voltage: 2mm
(2) Capacitance of empty cup: 60±2pF
(3) The max testing voltage: power frequency 2000V
(4) Dielectric loss of empty cup: tgδ<1×10-4
(5) Liquid capacity: about 40ml
(6) Electrode material: stainless steel
(7) Volume: 700mm(D)*120mm(H)

Dielectric Loss Testing
The tetsting voltage is sychronizely imposed to standard capacitor and oil cup's adding-voltage pole, The testing circuit comes to PGA controlling for  two circuit signals, then sychronizely take AD samples of the two channels' signals. Then transmit digital signals to DSP(digital signal precessor), DSP carries on filtration, FFT calculation to figure out tgδ,Cx,ε and other parameters, finally transmit to CPU. 

Main Parameters
1 Using terms -5ºC~40ºC; RH<80%
2 Power AC 220V±10%, no limitation to frequency
3 High voltage output 1000V~2200V, per 200V
4 Accuracy 2%
5 Capacity 50VA, output current 25mA
6 Temperature controlling induction furnace the max power 500W
7 Temperature controlling range <100ºC
8 Temperature testing error ±0.5ºC
9 Temperature controlling error ±1ºC
10 Temperature controlling time room temperature 90ºC; less than 20min
11 Measurement range tgδ(no limitation); Cx(15pF-300pF); Rx(10M-10T)
12 Accuracy tgδ: ±(reading*1.0%+0.02%)
Cx: ±(reading*1.0+0.5pF)
Rx: ±(reading*10%)
13 Relative Dielectric Constant εr: auto calculate
14 Volume Resistivity ρ: auto calculate
15 Sizes 450(L)*310(W)*360(H)
16 Weight 18kg

Company Information:
Kiyu Power is a high-tech enterprise professionally engaged in R & D, manufacture and marketing of power testing products, instruments, power industry automation systems for 20 years.We export completed set to Korea, Singapore, Vietnam, India, Ecuador, Paraguay, Pakistan, Philippines, Russia, Italy, Austria, Portugal, Chile such as PD test system, impulse voltage generator, temperature rising test system, transformer comprehensive test system, cable fault detect system and varies of instruments for transformer, circuit breaker, switchgear, lightning arrestor, insulator, cable, battery, SF6 gas and so on.
Transformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing EquipmentTransformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing EquipmentTransformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing EquipmentTransformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing EquipmentTransformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing EquipmentTransformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing EquipmentTransformer Insulation Oil Dielectric Loss Tester Insulation Liquid Tan Delta Testing Equipment

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI249120". Items marked "verified" are certified.

Watch Video
Watch Video
Kiyu Power Wuhan Co., Ltd
Kiyu Power Wuhan Co., Ltd
Kiyu Power Wuhan Co., Ltd
Kiyu Power Wuhan Co., Ltd
Kiyu Power Wuhan Co., Ltd
Kiyu Power Wuhan Co., Ltd
Kiyu Power Wuhan Co., Ltd
Kiyu Power Wuhan Co., Ltd

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 8, Fuzhi Road, Hengdian Street, Huangpi District, Wuhan City, Hubei Province, Wuhan, Hubei, China
verified Plant Area
6000 square meters
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port
verified Minimum Order Quantity
1 Set
verified Supply Chain Partners
346

Our Production Capability & Technical Expertise

Main Products
Oil Transformer, Impulse Voltage Generator, Vlf Hipot Test Equipment, Loop Resistance Tester, Relay Protection Tester, Pd Test System, Cable Fault Tester, Tuning Resonance Test Device, DC Hv Generator, Lightning Arrester
verified Production Lines
4
verified Production Machines
Injection Machine, Injection Molding Machine, Winding Machine
verified QA/QC inspectors
7 people
verified Inspection Type for Finished Products
100% inspection(Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Full Customization, Customization from Designs, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
4 people
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Export Year
4 Years
verified Main Markets
North America, Europe, Domestic
verified Repeat Buyers Choice
30%~50%
verified Number of Foreign Trading Staff
1
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
Yes

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now